| Items |
Standards |
Requirements |
Result |
| GreenGuard Gold |
UL 2818 – 2013 Gold Standard for
Chemical Emissions for Building Materials, Finishes and |
Refer to Standards |
Pass |
| Certified |
Furnishings |
| Floorscore |
SCS-EC10.3-2014v3.0 |
Refer to Standards |
Pass |
| Certification |
| CE Certification |
EN14041 |
Refer to Standards |
Pass |
| Fire resistance |
EN 9239-1 |
Critical Fluxf≥8.0kW/m2 |
Bfl-S1 |
| EN ISO11925-2 |
Fs≤150mm within 20s |
| EN 13501-1 |
Smoke≤750% minutes |
| Phthalate tests |
EN 14372:2004 |
N/A |
Free |
| (DBP/BBP/DEHP/DINP/ |
| DNOP/DIDP) |
| Dimension stability |
ASTM F2199-09(R2014) |
≦0.25% |
Manufacturing direction:-0.046% |
| Across-manufacturing direction:- 0.009% |
| Seam strength |
EN 684:1995 |
N/A |
Ave.:360N/50mm Pass |
| Min.:330N/50mm |
| Residual indentation |
ASTM F1700-13a & |
Average value≦8 |
0.4 Pass |
| (%) |
ASTM F1914-07(2011) |
Individual value≦10 |
| Resistance to chemicals |
ASTM F1700-13a & |
No more than a slight change in surface dulling,surface attack,or staining |
No change in surface dulling,surface attack,or staining was detected |
| ASTM F925-13 |
| Heat stability |
ASTM F1514-03(R2013) |
△E*ab< 8 |
△E*ab=0.67 Pass |
| Static loading |
ASTM F970-17 |
N/A |
0.04mm Pass |
| Soluble heavy metal contents
test |
ASTM F963-16(Clause 8.3) |
N/A |
Free |
| Large ball impact resistance |
NALFA/ANSI LF-01-2011 |
N/A |
No cracks or fractures occurred at the height of 2500mm |
| Static Electrical Propensity |
EN 1815:2016 method A |
≦2kV |
0.2kV |
| Sound Transmission Class |
ASTM E90-2009(R2016) |
N/A |
STC=68 |
| ASTM E413-10 |
| Formaldehyde |
ISO 17226-1:2008 |
N/A |
Free |
| Surface Bond |
NALFA/ANSI LF-01-2011 |
N/A |
1.14MPa Pass |
| Resilient floor covering Determination of peel resistance |
EN ISO 24345:2012 |
≥54N/50mm |
Longitudinal direction:95N/50mm |
| Cross direction:95N/50mm |
| Castor chair Resistance(25000 Cycles) |
NALFA/ANSI LF-01-2011 |
N/A |
No damage was found after test |
| ISO4918:2016 |
| Thermal conductivity |
EN 12667:2001 |
N/A |
0.154 W/(m.K) |
| Thermal Resistance |
EN 12667:2001 |
N/A |
0.033(m2.K)/W |
| Colour Fastness |
EN ISO 105-B02:2014 |
N/A |
Grade 6 |
| Curling |
ISO 23999:2008 |
N/A |
Average: 0.5mm Pass |
| Locking strength |
ISO 10582:2017 Annex D |
Class 32, |
Long side(X): 7.6 kN/m |
| type I:≥1.5kN/m |
Short side(Y): 6.3 kN/m Pass |
| Resistance to staining |
ISO 26987:2008 |
N/A |
Index 0: Not affected Pass |
| Slip resistance |
DIN 51130:2014-02 |
N/A |
Critical angle of inclination: 14.8°Classification: R10 Pass |
| (oil-wet ramp test) |
| Resistance to bacteria |
ISO 846-1997 Method C |
N/A |
Assessment of bacteria growth: 0
Pass |